< Previouswww.humboldtmfg.com • 1.800.544.7220 • 708.468.6300 278 ASPHALT Asphalt Binder Testing— Flash Point H-2095 H-2100 H-2085 Cleveland Flash and Fire Point Tester ASTM D92, D117; AASHTO T48 Used to determine flash and fire points by the Cleveland open-cup method. Consists of elec- tric Heater with rheostat, flash point platform with Thermometer holder, test burner and flash cup. Utilizes a 1250W-10 amp, nickel-chromium heater with step-less variable control for accu- rate, repeatable, rate-of-rise temperature settings per specifications. Heater is enclosed in a stain- less steel housing with cooling vents. Thermometer position is adjustable and provides the ability to raise the thermometer out of the way to facilitate the placement and removal of the test cup. Test flame requires a gas supply and the test flame can be adjusted through the use of the built-in needle valve. Order thermometer separately. Cleveland Flash Tester, 115V 60HzH-2085 Cleveland Flash Tester, 220V 50/60HzH-2085.4F Shipping wt. 14lbs (6.3kg) Cleveland Flash and Fire Point Tester ASTM D92, D117; AASHTO T48 Used to determine flash and fire points by the Cleveland open-cup method. Consists of a Hum- boldt, high-temperature burner, which is directly attached to the test support stand, for sample heating with a built-in, gas line extension for the test flame. Test flame burner and the heating burner include separate, integral, adjustment con- trols for regulating the flame. Includes flash point platform with thermometer holder, test burner and flash cup. Thermometer position is adjustable and provides the ability to raise the thermometer out of the way to facilitate the placement and removal of the test cup. Flame size is adjustable through the use of the built-in needle valve. Order thermometer separately. Cleveland Flash Tester, GasH-2095 Shipping wt. 15lbs (6.8kg) Cleveland Flash and Fire Point Tester ASTM D92, D117; AASHTO T48 Used to determine flash and fire points by the Cleveland open-cup method. Consists of a free-standing, Humboldt, high-temperature burner and a separate test flame burner, which is directly attached to the test support stand. Test flame burner and the heating burner include sep- arate, integral, adjustment controls for regulating the flame. Includes flash point platform with Ther- mometer holder, test burner and flash cup. Thermometer position is adjustable and provides the ability to raise the thermometer out of the way to facilitate the placement and removal of the test cup. Flame size is adjustable through the use of the built-in needle valve. Order thermometer separately. Cleveland Flash Tester, Natural GasH-2100 Shipping wt. 19lbs (8.6kg) DescriptionModel Electric heater with rheostat (1250W) H-2085.1 Flash-point platform H-2085P Test burner w/ holder H-2112 Flash cup H-2060 Supra-board plate H-2095.4.2 Thermometer* H-2600.11F Replacement Parts/Accessories DescriptionModel Cast-iron support baseH-21335 Support rodH-21370 High-temp. burnerH-5550 Test burnerH-2112 Flash cup platformH-2111 Flash cupH-2060 Thermometer clampH-8900 Thermometer*H-2600.11F Replacement Parts/Accessories Replacement Parts/Accessories DescriptionModel Cast-Iron support baseH-21335 High-temp burner w/ adjustable valve orifice H-5605X Test burner w/ holderH-2112 Flash-point platformH-2095P Supra-board plateH-2095.4.2 Platform coupling assemblyH-2095.5 Flash cupH-2060 Thumb screwH-3050.7 Thermometer*H-2600.11F CAUTION These thermometers contain mercury. There are restrictions on their sale and shipment. Please check laws in your area or contact us before ordering. Due to Illinois law, Humboldt must drop-ship these items from New Jersey. Mercury Thermometers require ground shipment in the U.S. Not sold outside United States. CAUTION *www.humboldtmfg.com • 1.800.544.7220 • 708.468.6300 ASPHALT 279Asphalt Binder Testing— Particle Charge, Distillation H-1550 Particle Charge Meter Set ASTM D7402; AASHTO T59 The particle charge meter identifies cationic emulsified asphalts by the migration of the par- ticles to a negatively charged electrode (cathode) by means of a direct current. Allows selection of emulsified asphalts that are compatible with the available aggregate or sand. Set includes particle charge meter with positive- and negative-identi- fied electrodes; a set of two H-2452 steel plates. Particle Charge Meter Set, 110V 60HzH-2450 Particle Charge Meter Set, 220V 50/60HzH-2450.4F Shipping wt. 12.9bs (1.3g) Particle Charge Meter Stainless Steel Plates ASTM D7402; AASHTO T59 Set of two 1" x 4" (25.4 x 101.6mm) stainless steel plates for use with H-2450. Particle Charge Meter PlatesH-2452 Shipping wt. 0.3lbs (.1kg) Solubility of Bituminous Materials Test Set ASTM D4, D2042; AASHTO T44 Test set is used to determine the degree of solubil- ity in trichloroethylene of asphalt materials having little or no mineral matter. The portion that is solu- ble represents the active cementing constituents. Solubility of Bitumen Material Test SetH-1550 Shipping wt. 6lbs (2.7kg) Distillation Set for Residue and Oil Distillate in Emulsified Asphalts ASTM D6997; AASHTO T59 The distillation set is designed to meet the require- ments of the Standards listed above. Use of this set will allow the user to accurately determine the representative portion of residue in emulsified asphalts. Two models are available, The H-2285 uses the large H-2345 still and the H-2290 uses the small H-1871 still. For a detailed explanation of the test procedure refer to the ASTM or AAS- HTO standards listed above. The complete set is comprised of the items listed in the chart below. Order H-2600.7F thermometer separately. Distillation Set for Emulsified AsphaltH-2285 Shipping wt. 28lbs (12.7kg) Distillation Set for Emulsified AsphaltH-2290 Shipping wt. 30lbs (13.6kg) Distillation Set Components DescriptionModel Still, aluminum, small H-1871 Ring burnerH-1876 Support stands (2 in set)H-21212 Support standH-21232 Support shelfH-21700 BurnerH-6220 CondenserH-2340 Graduated cylinderH-4915.100 Tube shieldH-2330 Straight glass tubeH-2290B Bent glass tubeH-2290A AdapterH-1910.4 Clamp, brass H-8325 ClampH-8390 Clamp holders (2 in set)H-8342 ClampH-8522 Rubber tubingH-4998 Still stopper (1)H-2345TTS Stopper, ptfeH-2345TS Stoppers, rubber (2)H-2340RS Stopper, rubberH-1910.7S H-21232 H-21700 H-1910.4 H-2340 H-8390 H-21212 H-21212 H-2330 H-6220 H-2290A (concealed) purchase separately H-2600.7F H-8342 H-8342 H-8522 H-2345 or H-1871 H-1876 H-8325 H-2285 or H-2290 H-2340RS H-2290B H-4998 H-2340RS H-1910.7S H-2345TTS H-2345TS H-1910.4 H-4915.100 H-2450 H-1550 PartsModel Gooch crucible, 28mlH-1550.1 Crucible holderH-1550.2 Buchner funnelH-1550.3 Stopper with #7 holeH-1550.5 Filters, glass fiber, 10pkH-1550.8 Flask, 125mlH-1883 Rubber tubingH-1448RT Filter pump, ChapmanH-12020 Erlenmeyer flask, vented 500mlH-4913.500 CAUTION These thermometers contain mercury. There are restrictions on their sale and shipment. Please check laws in your area or contact us before ordering. Due to Illinois law, Humboldt must drop- ship these items from New Jersey. Mercury Thermometers require ground shipment in the U.S. Not sold outside United States. CAUTION * Digital and mercury-free thermometers, see pages 326-329, 331-332, 334 . ACCESSORIESwww.humboldtmfg.com • 1.800.544.7220 • 708.468.6300 280 ASPHALT H-8572 H-2435* H-2430.3 H-8325 H-21232 H-1876 H-8325 H-1871 H-2440, H-2442 H-21232 H-2430.1 H-2435* H-2430.3 H-8572 H-2430.4 H-2430 H-8325 Distillation Set for Cut-Back Asphaltic Products ASTM D402; AASHTO T78 The H-1910 and H-1910E distillation sets are designed to meet the requirements of the Standards listed above. Use of this set will allow the user to measure the amount of the more volatile constituents in cutback asphaltic products. For a detailed explanation of the test procedure refer to the ASTM or AASHTO standards listed above. The complete set is comprised of the items listed in the following charts. Order H-2600.8F thermometer separately. Distillation Set, Cut-Back Products, gasH-1910 Distillation Set, Cut-Back Products, elecH-1910E Shipping wt. 24lbs (10.9kg) Dean Stark Moisture Test Apparatus, Electric ASTM D95, D244, D1461,E123; AASHTO T59, T110 The dean stark moisture test apparatus is used to determine the water content in petroleum prod- ucts, tars, emulsified asphalts and other bitumi- nous materials by the distillation method. The distillation process allows the water in the test sample to be isolated and collected in the receiver of the Trap. This model uses a glass flask, which Dean-Stark, Electric-Heated, 10mlH-2430 Dean-Stark, Electric-Heated, 25mlH-2430.4F Shipping wt. 30lbs (13.6kg) Dean Stark Moisture Test Apparatus, Gas Type ASTM D95, D244, D1461, E123; AASHTO T59, T110 The Dean Stark moisture test apparatus is used to determine the water content in petroleum prod- ucts, tars, emulsified asphalts and other bitumi- nous materials by the distillation method. The dis- tillation process allows the water in the test sam- ple to be isolated and collected in the receiver of the Trap. This model uses an aluminum still, which is heated by a gas, ring burner. The complete set is comprised of the items listed in the table below. Dean-Stark, Gas-Heated, 20mlH-2440 Dean-Stark, Gas-Heated, 10mlH-2442.10 Dean-Stark, Gas-Heated, 25mlH-2442.25 Shipping wt. 30lbs (13.6kg) DescriptionModel FlaskH-1910.3 CondenserH-1910.1 AdapterH-1910.4 Distillation shieldH-1940 Graduated cylinderH-4915.100 ClampH-8002 Support standH-21212 Wire gauzeH-25885 Stopper, rubberH-1910.7S Stopper, rubberH-1910.1S Stopper, corkH-1910.6 H-1910E Only Electric Heater 0-750WH-2430.1 Platform JackH-14005 DescriptionModel Electric, heater 0-750WH-2430.1 Flask, 500mlH-2430.3 Distillation trap, 25ml, or 10ml H-2435.25 H-2435.10 Condenser, liebigH-2430.3 Support standH-21232 Clamp, brassH-8325 Clamp, round jaw, coatedH-8572 DescriptionModel Ring burnerH-1876 Aluminum still, 0.95LH-1871 Distillation trap, 20ml, 25ml, or 10ml H-2435.25 H-2435.10 Condenser, liebigH-2430.3 Support standH-21232 Clamp, brassH-8325 Clamp, round jaw, coatedH-8572 H-1910 Only DescriptionModel BurnerH-6220 Flame shieldH-1945 Support ringH-18355 Support standH-21222 Support shelfH-21700 H-6220 H-1945 H-21222 H-21700 H-18355 Asphalt Binder Testing— Distillation H-4915.100 H-21212 H-1910.7S H-1910.1 H-1910.3S AY1087X1 H-8002 H-14005 H-1910.3 H-1940 H-1910.6 H-1910.4 H-2430.1 H-1910E H-1910www.humboldtmfg.com • 1.800.544.7220 • 708.468.6300 ASPHALT 281 Asphalt Binder Testing— Distillation H-2345 H-2348 H-2340 H-1945 H-1876 H-1946 Still, Aluminum ASTM D95, D244, D1461, D6997, E123; AASHTO T59, T110 Used primarily in standards for determining water in crude petroleum, tars and derivatives of those materials. Large model, 3.75" x 9.5" (95mm x 241mm) ID, has three tubulures, two drilled 10/18 and one drilled 24/40). The small model, 3.5" x 6" (89mm x 152mm) ID, has a 1 qt, (0.95L) capacity and one tubular. Both are cast aluminum. Still, Large AluminumH-2345 Still, Small AluminumH-1871 Shipping wt. 6.5lbs (2.9kg) Stoppers for Stills Teflon stoppers for use with H-2345 and H-1871 . Stopper for Glass TubingH-2345TS Stopper for ThermometerH-2345TTS Shipping wt. 0.2lbs (0.09kg) Gasket, Still Replacement Compatible with: H-2345 and H-1871. Dimensions: 6.25'' OD X 3.6875'' ID Still Replacement GasketH-2345G Shipping wt. 0.2lbs (0.09kg) Ring Burner ASTM D244; AASHTO T59 Can be used with all gases. 4.75" (121mm) ID x 5.5" (140mm) OD. Overall shank length is 11" (279mm) with .375" (10mm) serrated hose connection. Guide pins keep burner equidistant around still. Fletcher attachment regulates gas and air. Ring BurnerH-1876 Shipping wt. 1.4lbs (.63kg) Glass Stirring Rod ASTM D244 Dimensions: 7" x 1/4" Glass Stirring RodH-2444 Shipping wt. 0.5lbs (.22kg) Distillation Shield ASTM D402; AASHTO T78 Use with H-1910. Flanged, open-end, stainless steel cylinder with .125" ceramic lining and two-part cover. For use with 500ml flask. Flame distillation only. Distillation ShieldH-1940 Shipping wt. 1.5lbs (.68kg) Flame Shield ASTM D402; AASHTO T78 Use with H-1910. Stainless steel, spot-welded cone 2" (51mm) dia. at bottom with spring clip to fit 7/16" to .625" (11 to 16mm) burner tubes. Distillation ShieldH-1945 Shipping wt. 0.3lbs (.1kg) Burner Chimney Fits standard 4" (102mm) rings. Burner ChimneyH-1946 Shipping wt. 3lbs (1.3kg) Condenser Jacket ASTM D244; AASHTO T59 For use with H-2285 and H-2290. Brass, 15" long inlet/outlet tubulures on opposite sides of jacket. Condenser JacketH-2340 Shipping wt. 3lbs (1.3kg) Connecting Tube Shield ASTM D244; AASHTO T59 For use with H-2285 and H-2290. Stainless steel. Connecting Tube ShieldH-2330 Shipping wt. 1lbs (.45kg) Still Cleaner Use with H-1871 and H-2345. Tool to remove res- idue from interior of still, 13" x 4" (328 x 101mm) diameter. Still CleanerH-2348 Shipping wt. 1.3lbs (.58kg) Glass Distillation Trap, 25ml ASTM D95, D1461; AASHTO T78 25ml distillation trap graduated 0.1ml from 0 to 25ml. Glass Distillation Trap, 25mlH-2435.25 Shipping wt. 1.1lbs (.49kg) Glass Distillation Trap, 10ml ASTM D95, D1461; AASHTO T78 10ml distillation trap graduated 0.1ml from 0 to 1ml and 0.2ml from 1ml to 10ml. Glass Distillation Trap, 10mlH-2435.10 Shipping wt. 1lbs (.49kg) Glass Distillation Trap, 5ml ASTM D95, D1461; AASHTO T78 5ml distillation trap graduated 0.1ml. Glass Distillation Trap, 5mlH-2435.5 Shipping wt. 1lbs (.45kg) Glass Distillation Trap, 20ml 20ml distillation trap graduated 0.1ml. Glass Distillation Trap, 20mlH-2435.20 Shipping wt. 1.5lbs (.68kg) H-2435.25 H-2435.20 H-2435.5 H-2435.10 H-2444 H-1871 H-1940 H-2330 H-2345TS H-2345TTS H-2345Gwww.humboldtmfg.com • 1.800.544.7220 • 708.468.6300 282 ASPHALT Asphalt Binder Testing— Rice Test Vacuum Pycnometer Set (4.34L) for Rice Test ASTM D2041; AASHTO T209, T283 Used in rice testing to determine the maximum specific gravity of bituminous paving mixtures with maximum aggregate size up to 19.1mm (.75"). The H-1750 provides a 4.34L volume with a 2.9L max. sample volume and typically a 2500g required sample size and a 7.5" ID x 6" depth. Set includes aluminum volumetric canister; volumetric lid; flat, vinyl vacuum lid with O-ring and a metal water vacuum aspirator with 3/8" IPT and 6' hose with release valve and fittings. Unit achieves vac- uum using an aspirator or optional vacuum pump. This set is also available in stainless steel, order H-1750SS. For those who want to use smaller test samples, the H-1751 is available. The H-1751 provides a 2.9L volume with a 1.9L maximum sample volume for a typical sample size of 1500g. It measures 7.5" ID x 4" depth, but the H-1751 does not comply with ASTM specs. A larger volume model pycnometer is also avail- able. It provides a 5.8L volume with a 3.9L maxi- mum sample volume and a 4000g typical sample size. It measures 7.5" ID x 8" depth. All models can be used with H-1756A vibrat- ing apparatus or H-1782 de-airing device, and H-1754D manometer, sold separately. See page 284 for vacuum pumps. Replacement parts are available, please inquire. Vacuum Pycnometer Set, 6" (4.34L)H-1750 Vacuum Pycnometer Set, SS, 6" (4.34L)H-1750SS Vacuum Pycnometer Set, 4" (2.9L)H-1751 Vacuum Pycnometer Set, 8" (5.8L)H-1755A Ship wt. 13lbs. (5.8kg) Pycnometer Replacement Lid Replacement lid for models H-1750, H-1751 and H-1755A. Pycnometer Replacement LidH-1750.2 Ship wt. 4lbs. (1.8kg) Pycnometer Lid, O-Ring Replacement o-ring for models H-1750, H-1751 and H-1755A. Pycnometer Lid, O-RingH-1750.3 Ship wt. 0.05lbs. (0.02kg) Vacuum Pycnometer Set, Large-Capacity AASHTO T209, T283 Large-capacity unit, 10L (2.64 gal.), 6000g (13.2 lbs.) sample weight, with maximum aggregate size of 50mm (2"). The set features a domed, transparent cover for easy observation of sam- ple testing, perforated plastic shelf, which some States require; water inlet valve and .25" ID hose, quick-disconnect, vacuum gauge, vacuum hose and aspirator with 3/8" NPT fitting. Flange OD is 10.75" (273mm); maximum clearance above plate is 7.75" (197mm). Use with H-1826A.3F vibrating table, and H-1754D manometer, sold separately. See page 284 for vacuum pumps. Replacement parts are available, please inquire. Dimensions: 9.5" ID x 12.125" (240 ID x 311mm) Vacuum Pycnometer Set, LargeH-1820 Ship wt. 10lbs. (4.5kg) Slow-Release Valve for Vacuum Pycnometers ASTM D2041; AASHTO T283 For use with H-1750, H-1755SS, H-1751, H-1755A and H-1820 for greater accuracy and shorter dry back time. Brass valve maintains 30mm vacuum pressure on sample. Valve, Slow-ReleaseH-1749 Ship wt. 0.6lbs. (.2kg) Aspirator Filter Pump Provides excellent performance for providing a vacuum for pycnometer applications. Water inlet is .375" and length is 5.375" (137mm). Nick- el-plated with serrated tail and side arm. Aspirator Filter PumpH-12090 Ship wt. 0.25lbs. (.11kg) Manometer, Digital A precise measurement device designed to replace mercury-filled manometers used in Rice test applications. This portable, hand-held device can be easily moved around the laboratory. Holes are provided for bench or wall mounting and a .375" barb fitting is used for quick connections. The instrument features a digital display range of 0 to 1000mm Hg (absolute) at a resolution of 0.1mm Hg. The device has a rated accuracy of +/-0.5% full scale and is powered by one 9V bat- tery or AC adapter, both are included. Manometer, Digital, 120V 60HzH-1754D Manometer, Digital, CertifiedH-1754D-CA Manometer, Digital, 220V 50/60HzH-1754D.4F Manometer, Digital, CertifiedH-1754D.4F-CA Ship wt. 2lbs. (.9kg) H-1820 H-1750 H-1749 H-1750 H-1755A H-1751 Pycnometer Size Comparison. H-12090 H-1754D Typical Rice Test Setupwww.humboldtmfg.com • 1.800.544.7220 • 708.468.6300 ASPHALT 283Asphalt Binder Testing— Rice Test H-1753 Flask Not Included De-airing Agitator ASTM D2041; AASHTO T209, T283 Heavy-duty, vibrating, de-airing agitator for use with H-1750, H-1750SS, H-1751 and H-1755A pycnometers keeps sample material loose for more reliable test results. Strong, rugged-duty vibrators and sturdy bases having integral, heavy- duty on/off switches. Exclusive quick-release cam/ lock fasteners allow quick placement and removal of canister. De-airing Agitator, 120/220V 50/60Hz H-1756.3F Shipping wt. 16 lbs (7.2kg) De-airing Agitator, Large AASHTO T209, T283 For use with the H-1820 large pycnometer. Heavy-duty vibrating Apparatus keeps sam- ple material loose for more reliable test results. Strong, rugged-duty vibrators and sturdy bases having integral, heavy-duty on/off switches. Exclusive quick-release cam/lock fasteners allow quick placement and removal of canister. De-airing Agitator, 120/220V 50/60Hz H-1826.3F Shipping wt. 18 lbs (8.16kg) De-Airing Flask Attachment For use with H-1756.3F and H-1782, flask not included. De-Airing Flask Attachment H-1753 Shipping wt. 1.3 lbs (.58kg) Orbital De-Airing Device The Humboldt orbital de-airing device is designed for use in maximum specific gravity and density determinations of bituminous paving mixtures. Through the use of an orbital shaking action, material densification that entraps air is virtually eliminated, resulting in more accurate and uniform test results. The front panel incorporates a vari- able speed controller with a range of 10 to 250 rpm and an LED programmable timer with an accuracy of better than ±0.1%. The orbital diame- ter of the 11" x 12" (279 x 305mm) platform is set at 1.5" (38.1mm). Taking up little counter space, the base is 10" x 10" (154 x 154mm) and has an overall height of 16" (406mm). Quick release clamps are used to permit quick mounting and removal of the pycnometer. The optional H-1753 flask attachment allows the user to conduct tests using a laboratory flask. Orbital De-Airing Device, 110V 60Hz H-1782A Orbital De-Airing Device, 220V 50/60Hz H-1782.4F Shipping wt. 38 lbs (17kg) AutoRice Controller ASTM D2041; AASHTO T209, T283 The AutoRice is an automatic control unit allow- ing laboratory technicians to quickly conduct and monitor specific gravity tests with the press of a button. Designed to accurately control and monitor the vacuum pressure, vacuum time and shaker vibration frequency for the Rice test, ASTM D2041 and AASHTO T209. The AutoRice ensures more consistent inter-laboratory repeatability and accuracy. The AutoRice will start the vacuum pump, regulate the vacuum pressure, precisely control the vacuum time and monitor the shaker frequency. Currently, the AutoRice acceleration monitor and shaker frequency is a parameter that is not monitored during the test. Data from the Rice test can be downloaded via the USB port, where results can be reviewed to assure accuracy and adherence to test specifications. The unique, compact design allows AutoRice to fit on a bench top or mount to a wall and works with glass flasks and metal container setups. Features: •Reduces operator errors by automating test parameters; improving accuracy and repeatability •Measures shaking frequency and acceleration to prevent stripping damage to the sample •Automates saturation process for AASHTO T283 (moisture damage) •Provides capability to enter weights and calcu- late max specific gravity results •Replaces digital vacuum gauge used in Rice setup •Stores test records (vacuum pressure, vacuum time, frequency and acceleration) •Easy setup with menu driven software •The AutoRice can output test data to a portable USB drive. AutoRice Controller HA-1665 Ship wt. 25lbs. (11.4kg) PumpSaver The PumpSaver is a unique new method for the removal of moisture in air prior to entering a vac- uum pump. The device extends the life of vacuum pumps by reducing the amount of water entering the pump. It also increases pump efficiency by offering a lower resistance to air flow as opposed to a desiccant style air drier that actually inhib- its the free flow of air. Using the PumpSaver also eliminates the requirement for a desiccant type air drier and eliminates the need to contin- ually replace or recycle desiccant materials. The PumpSaver is used to improve the accuracy, efficiency, reliability and repeatability of your tests requiring a vacuum pump, such as the Rice test, H-1756.3F H-1826.3F H-1782A HA-1665www.humboldtmfg.com • 1.800.544.7220 • 708.468.6300 284 ASPHALT Asphalt Binder Testing— Rice Test H-1763A H-1759 H-1758 H-1757 ASTM D2041 and AASHTO T209. PumpSaver connects to your vacuum pump and acts as a moisture trap eliminating the need for desiccants or in-line moisture filters to protect the pump from moisture damage. •Reduces the number of oil changes per year •Improves efficiencies •Eliminates flow restricting desiccant cartridges •Increases pump life and efficiencies PumpSaver HA-1666 Ship wt. 5lbs. (2.3kg) AutoRice USB Shaker Sensor AutoRice USB Shaker Sensor HA-1667 Ship wt. 2lbs. (0.9kg) Indicating Drierite Air Drying Unit Easily installs in-line between vacuum pump and rice test equipment. This refill- able unit measures 2.625" by 11.375" (667 x 289mm) with hose barbs at both ends, which can accept 0.25" to 0.375" flexible tubing. Supplied complete with 650g of 8 mesh, indicating desiccant. Indicating Drierite Air Drying UnitH-1759 Shipping wt. 3.1 lbs (1.4kg) Indicating Drierite Desiccant ASTM D2041 Indicating drierite is impregnated with cobalt chlo- ride. This desiccant is blue when dry and changes to pink upon absorption of moisture. The color change is pronounced and clearly visible. This makes indicating drierite valuable when it is nec- essary to know with certainty that dryness is being maintained and to signal when the drying agent should be replaced. It has the same efficiency as regular drierite and can be regenerated for reuse. Indicating Drierite Desiccant, 1lb/8 meshH-1758 Shipping wt. 2 lbs (.9kg) Indicating Drierite Desiccant, 5lb/8 meshH-1761 Shipping wt. 10 lbs (4.5kg) Drierite Desiccant, 8 mesh ASTM D2041 Replacement desiccant for air drying unit. Pro- tects vacuum pump by removing final traces of moisture. Drierite Desiccant, 1 lbH-1757 Shipping wt. 2.5 lbs (1.1kg) Drierite Desiccant, 5 lbH-1767 Shipping wt. 9 lbs (4kg) High Vacuum Pump Direct-drive two-stage rotary sliding vane high vac- uum pump features gas ballast and trap to reduce risk of oil being sucked into the system. Produces free air displacement 85L per minute (3 cu. ft. per minute) and maximum vacuum 29-30". Operating temperature is 30 to 170°F (-1.11 to 76.6°C). Has 0.25" OD intake ports for 0.25" ID tubing. Dimen- sions: 11.25" x 15.5" x 6.5" (28.6 x 39.4 x 16.5cm). High Vacuum Pump 120V 60HzH-1763A High Vacuum Pump 220V 50/60HzH-1763A.4F Shipping wt. 31 lbs (14kg) Two-Stage Oil-less Vacuum Pump Split-capacitor four-pole, two-stage oil-less diaphragm vacuum pump pulls 29" Hg maxi- mum-obtainable vacuum. Two-Stage Pump, 120V 60Hz H-1762 Two-Stage Pump, 230 50/60Hz H-1762.4F Shipping wt. 25.7 lbs (11.6kg) Two-Stage Vacuum Pump Designed for continuous use, this two-stage, belt- driven pump operates on the oil-sealed rotary vane principle and is ideal for distillation, filtration, degassing and as a roughing pump for high-vac- uum systems. Pumps are mounted on rectangular steel base plate and include V-belt and belt guard that totally encloses belt and pulleys. Pump pulls 29-30" maximum vacuum. Includes initial supply of oil plus an extra quart of HyVac ® oil. Two-Stage Pump, 120V 60Hz H-1764A Two-Stage Pump, 230 60Hz H-1764A.2F Two-Stage Pump, 230 50Hz H-1764A.5F Shipping wt. 55 lbs (24.9kg) Vacuum Pump High-vacuum, small capacity, general-purpose vacuum pump with belt guard has two-stage construction for efficiency with low maintenance. Features metal vanes and vented exhaust for introduction of air to remove condensible vapors. Pump is filled with oil; an extra quart is included. Exhaust filter is available separately. Guaran- teed ultimate vacuum is 25-29" (635-736mm) mercury, and free-air displacement is 25L/min. (0.9cfm). Vacuum Pump, 120V 60HzH-1770 Shipping wt. 80 lbs (36kg) H-1762 H-1764A H-1770 HA-1666www.humboldtmfg.com • 1.800.544.7220 • 708.468.6300 ASPHALT 285Asphalt Binder Testing— Rice Test DescriptionPart # Exhaust tubing, 3"ID (sold by foot)H-1515 Exhaust tubing, stainless, 3"ID (sold by foot) H-1515SS Printer paperPRX2 Baskets (set of 2)AY1087X6 Vacuum Pump Oil High purity oil with low vapor pressure that does not materially increase at temperatures up to 50°C (122°F) and viscosity sufficiently low for use at 125°C (59°F). Oil remains fairly constant up to 50°C (122°F). Vacuum Pump Oil, 1 Quart H-1766.2 Shipping wt. 3 lbs (1.3kg) Vacuum Pump Oil, 1 Gallon H-1766.3 Shipping wt. 9 lbs (4kg) Vacuum Pump Oil, 5 Gallon H-1766.4 Shipping wt. 41.2 lbs (18.6kg) Vacuum Pump Oil, 1-Qt. (Case of 12) H-1766.5 Shipping wt. 25 lbs (11.3kg) Vacuum Pump Oil,1 Gallon (Case of 6) H-1766.6 Shipping wt. 54.6 lbs (24.7kg) Flushing Oil for Vacuum Pumps, 1 gallon Purges contaminants and condensibles, such as water and solvents from all mechanical vac- uum pumps. Use between oil changes minimizes contamination of new oil by residue from old oil; extends pump life. Flushing Oil for Vacuum Pumps, 1 gal.H-1768.3 Shipping wt. 8.3 lbs (3.7kg) Digital Timer, Humboldt Humboldt’s portable digital timers automatically shut off electrical equipment at a set time. Two models are available, one for up to 60 minutes, the other up to 99 seconds. Feature easy-to-use digital interface and two-plug, AC receptacle. The accuracy for both versions is 0.5%. Digital Timer, Minute, 120V 50/60HzH-4296A Digital Timer, Minute, 220V 50/60HzH-4296A .4F Digital Timer, Second, 120V 50/60HzH-4299 Digital Timer, Second, 220V 50/60HzH-4299.4F Ship wt. 3lbs. (1.3kg) Universal Analog Timer Portable timer automatically shuts off electrical apparatus at set time up to 60 minutes. Features two-plug AC receptacle. Universal Analog Timer, 120V 60HzH-4296 Universal Analog Timer, 220V 50/60HzH-4296.4F Shipping wt. 2.6 lbs (1.1kg) Rhoma-Sol™ Specialty Emulsifier Spray-on solution used in the removal of asphalt and tack oil from testing, paving, oiling, patch- ing, reclaiming and other work zone equipment. Contains no hazardous petroleum solvents and is 100% biodegradable. Flammable, must ship by truck domestically and as Dangerous Goods Internationally. Rhoma-Sol™ Specialty Emulsifier H-1304 Shipping wt. 2 lbs (0.9kg) Asphalt Content/Binder Ignition Furnace ASTM D6307 The asphalt content/binder furnace with internal automatic balance is an environmentally-friendly and cost-effective method for the accurate deter- mination of asphalt content. Developed by NCAT, the National Center for Asphalt Technology. The furnace’s large capacity handles samples up to 4,000 grams. Ignition method reduces testing time compared to solvent testing methods and automatic operation frees technicians for other tasks. Temperature range is: 392 to 1202°F (200 to 650°C). 4,800 watt operation Accurate internal balance monitors weights automatically through- out ignition to within ±0.1 gram. Easy operation— simply enter sample weight, calibration factor, load the sample, and push start, when unit beeps at test end, push stop, and sign receipt. Door safety features, such as a software-activated door lock, an automatic interlock that cuts power when door is open, full 180 degree door opening and door hinge lock eliminate harmful solvents and make operation easy. Ignition Furnace comes complete with accessory package AY1087X1. CE-approved. Chamber dimensions: 14"W x 10.5"H x 14"D (355 x 266 x 355mm). Shipping dimensions: 32"W x 32"D x 60"H (813 x 813 x 1524mm).) Content/Binder Ignition Furnace w/ Accessory Package, 240V 50/60Hz, 20 ampF85930-33 Shipping wt. 383 lbs (173.7kg) Content/Binder Ignition Furnace w/ Accessory Package, 208V 60Hz, 23 ampF85938 Shipping wt. 280 lbs (127kg) Content/Binder Ignition Furnace (furnace only) 240V 50/60Hz, 20 ampF85930-33X Shipping wt. 357 lbs (161.9kg) Content/Binder Ignition Furnace (furnace only) 208V 60Hz, 23 ampF85938X Shipping wt. 230 lbs (104.3kg) Accessory Package for Ignition Furnaces Accessory package includes: 4 baskets, 2 trays, 2 covers, handle, cooling cage, insulated plate, gloves, face shield, 4 rolls of printer tape, balance calibration plate and anderol oil. Ignition Furnace Accessory PackageAY1087X1 Shipping wt. 75 lbs (34kg) F85930-33 F85938 AY1087X1 H-1304 H-1766.3H-1766.2H-1768.3 H-4296 H-4296A For gloves, see pages 374 . ACCESSORIESwww.humboldtmfg.com • 1.800.544.7220 • 708.468.6300 286 ASPHALT Asphalt Analysis— Binder Extraction Centrifuge Extractor (Explosion Proof) ASTM D2172; AASHTO T164 Available in 1500g and 3000g capacities, these extractors conform to the explosion-proof stan- dards for the safety of operating personnel. All models feature a removable aluminum bowl assembly, which quickly lifts out of the sealed housing for efficient specimen handling. A sim- ple, control knob adjusts bowl speed. The heavy, cast-aluminum bowl cover latches securely in place and features an integral solvent dispensing cup for easy pouring of the solvent into the bowl. Extractors are supplied complete with 25 filter discs. Replacement filter discs (100-packs) are available, see chart at bottom of page. Dimensions: both sizes: 18" x 18" x 18" (457 x 457 x 457mm). Extractor, 1500g, 115V 60HzH-1466 Extractor, 1500g, 220V 50/60HzH-1466.4F Extractor, 3000g, 115V 60HzH-1473 Extractor, 3000g, 220V 50/60HzH-1473.4F Shipping wt. 75lbs (34kg) Auto Centrifuge Extractor, (Explosion Proof) ASTM D2172; AASHTO T164 These extractors feature automated, auto control of the unit. Timer allows unit to run unattended for a specific period of time (1 to 10 minutes). Unit brakes and stops automatically when time expires and holds last test cycle settings in mem- ory for repeatable tests. Time and speed can be set quickly with the rotating dials below the digital display that shows the settings. The controller can also be wall- or remotely-mounted for visual ease as well as vibration isolation. Power is supplied by a reliable 1/8hp DC motor. Extractors are supplied complete with 25 filter discs. Replacement filter discs (100-packs) are available, see chart at bottom right of page. Extractor, 1500g, 115V 60HzH-1461 Extractor, 1500g, 220V 50/60HzH-1461.4F Extractor, 3000g, 115V 60HzH-1465 Extractor, 3000g, 220V 50/60HzH-1465.4F Shipping wt. 114lbs (51.7kg) Asphalt Centrifuge Extractor (Open Motor) ASTM D2172; AASHTO T164 This extractor is an open-motor version of the explosion-proof models described above. While it is safe to operate, it does not provide the added safety of the explosion-proof design. Available only in 1500g model, this extractor is a great eco- nomical choice or for those who need an extractor, but may not use it extensively. Extractor, 1500g, 115V 60HzH-1456 Extractor, 3000g, 115V 60HzH-1471 Shipping wt. 70lbs (31.7kg) Auto Centrifuge Extractor (Open Motor) ASTM D2172; AASHTO T164 This extractor is an open-motor version of the explosion-proof models described above. While it is safe to operate, it does not provide the added safety of the explosion-proof design. This extractor is a great economical choice or for those who need an extractor, but may not use it exten- sively. Not available in 220V model. Centrifuge Extractor, 1500g, 115V 60HzH-1460 Centrifuge Extractor, 3000g, 115V 60HzH-1464 Shipping wt. 76lbs (34.4kg) Filter Papers for Centrifuge Extractors Asphalt Centrifuge Extractor (Open Motor) ASTM D2172; AASHTO T164 This extractor is an open-motor version of the explosion-proof models described below. While it is safe to operate, it does not provide the added safety of the explosion-proof design. Dimensions: 12" x 20" x 22" (305 x 508 x 559mm); Extractor, 1500g, 115V 60HzH-1452 Shipping wt. 85lbs (38.5kg) Asphalt Centrifuge Extractor (Explosion Proof) ASTM D2172; AASHTO T164 The asphalt centrifuge extractor is designed for determining the percentage of bitumen in asphaltic mixtures. Available in 1500g and 3000g capacities, these extractors conform to the explo- sion-proof standards for the safety of operating personnel. All models feature a removable, alumi- num bowl assembly, which quickly lifts out of the sealed housing for efficient specimen handling. A simple, control knob adjusts bowl speed up to 3600 rpm, and, an electric brake stops the cen- trifuge in seconds when extraction is complete. The heavy, cast-aluminum bowl cover latches securely in place and features an integral solvent dispensing cup for easy pouring of the solvent into the bowl. Power is supplied by a reliable 1/8hp DC motor. Extractors are supplied complete with 25 filter discs. Replacement filter discs (100-packs) are available, see chart at bottom right of page. Dimensions: • 1500g units: 12" x 20" x 22" (305 x 508 x 559mm) • 3000g units: 14" x 20" x 22" (356 x 508 x 559mm) Extractor, 1500g, 115V 60HzH-1451 Extractor, 3000g, 115V 60HzH-1474 Shipping wt. 85lbs (38.5kg) Filter Papers for H-1451 & H-1474 Centrifuge Extractors H-1456 H-1461 Centrifuge Extractor Replacement Parts DescriptionModel Bowl for H-1456, H-1466H-1456B Bowl for H-1471, H-1473H-1471B Bowl cover, H-1456, H-1466H-1456BC Bowl cover, H-1456, H-1466H-1471BC Cover nutH-1471N Clamp, all modelsH-1471C O-Ring, all modelsH-1471RV Brake band, all modelsH-1456BB Brake band assembly, allH-1471BBA H-1451 Extractor / SizeModel H-1456, H-1466, H-1460, H-1461 (10"OD x 5"ID) H-1487.627 H-1471, H-1473, H-1464, H-1465 (12.25"OD x 5"ID) H-1489.627 H-1451.1 Extractor / SizeModel H-1451, H-1452 9.75"(241mm) OD x 2.5"(64mm) Hole H-1451.1 H-1474 11.75"(298mm) OD x 2.5"(64mm) Hole H-1474.1www.humboldtmfg.com • 1.800.544.7220 • 708.468.6300 ASPHALT 287Asphalt Analysis— Solvent Extraction Asphalt Solvent Recycler This unit has been designed to recycle the sol- vents used in asphalt extraction tests. It success- fully extracts pure solvent from the oil and wastes generated from the extraction process and gen- erates clean solvent ready for reuse in a new test. The unit reduces the need for new solvent and eliminates problems with solvent disposal. •Microprocessor controlled with easy-to-read LCD display and TouchView PLC •Custom programming for unique solvent requirements using Waste Solvent Mixture Wizard technology •Designed and built for multiple shift operations •Bag-lined tank allows easy removal of solid contaminants •Mobile; mounted on locking wheels for easy relocation with stabilizer bar for added support •Quiet operation and low maintenance •RTD probes monitor thermal oil and condenser temperatures •Oil is self-contained Solvent Recycler 120V 60HzH-1431A Solvent Recycler 220-240V 60HzH-1431A.2F Shipping wt. 290 lbs (132kg) Vacuum Extractor ASTM D2172 (Method E); AASHTO T164 Basic vacuum extractor for use in quantitative determinations of bitumen in hot-mixed paving mixtures and pavement samples. The H-1449 provides a 12" (305mm dia filtering surface. Unit includes a connecting hose, (100) H-1497.613 filter papers and test procedure instructions. Use with a 4,000cc Erlenmeyer flask and a vacuum pump, see below. For replacement filter paper, use H-1497 series paper from chart at bottom of page. Vacuum ExtractorH-1449A Shipping wt. 58.6lbs (26.5kg) Centrifuge Extractor, Filterless ASTM D1856; AASHTO T164 The continuous-flow filterless centrifuge extractor is ideally suited for use in the extraction of mineral fines from bitumen-laden solvents obtained from standard asphalt extraction tests. In operation, the solvent suspension is fed through the top fun- nel into a special aluminum beaker, (2) H-1857.5 supplied). Using the high, 11,000 rpm centrifugal force, the liquid moves up the beaker wall and out the overflow tube while the solids remain for easy removal at test completion. The system allows the continuous feeding of the suspension until the solids-retaining capacity of the beaker is reached. The unit is supplied complete with a No. 18 (1.0mm) and No. 200 (75μm) sieve for placement at the top of the inlet funnel. Using this arrangement, an asphalt mix extraction test can be carried out by pre-dissolving the mix with sol- vent and then pouring the sample into the sieve. Dimensions: 20" x 15" x 33" (508 x 380 x 840mm). Centrifuge Extractor, Filterless 120V 60HzH-1857A 230V 60HzH-1857A.2F 230V 50HzH-1857A.5F Shipping wt. 154lbs (69.8kg) Aluminum Beaker Replacement aluminum beaker for use with the filterless centrifuge extractor. Aluminum BeakerH-1857.5 Shipping wt. 2lbs (.9kg) H-1449A Vacuum Extractor Components & Accessories DescriptionModel Fluorosilicone o-ring H-1448.1 Stainless steel plate, heavy-duty H-1448HP Rubber TubingH-1448RT Clear, Heavy-wall, Vacuum Tubing H-1446 4,000cc Erlenmeyer flask, meets ASTM D2172 and AASHTO T164 (Method E) H-4913.4M High-vacuum pump (see page 149 for info) H-1763A H-1763A.4F H-1857A H-1431A DescriptionModel Capacity:7 gallons / 26 Liters Voltage: 120V 60Hz or 240V 60Hz Dimensions: (W x L x H) 22.25" x 39" x 44" (57cm x 99cm x 112cm) Distillation Rate:0.75-1.25 GPH Recovery Yields:85-98% Max. Operating Temp.: 206°C Estimated Cycle Time5.5-9.0 hours Filter Papers for Vacuum Extractors SizeFilter Speed Flow Rate (ml/min.) Thickness Retention (µm) Per Pkg.Model 33cm dia.Very fast3600.514850 H-1497.617 33cm dia.Very fast4351.0231100 H-1497.633 33cm dia.Fast2350.2524100 H-1497.615 33cm dia.Medium600.176100 H-1497.613 33cm dia.Medium850.714100 H-1497.627Next >